Clinton Hill Residents using their own Preferred Carpenter - 2023
Side
DUCT
PROFILE GRILLE
| STANDARD TOLERANCES(UNLESS OTHERWISE SPECIFIED) | DRAWN | 06/28/22 | KELVINPhone:(646)902-4328KEL.VINBrooklyn Navy YardBuilding 303 Suite 702Brooklyn,NY11205 | ||||
|---|---|---|---|---|---|---|---|
| ANGULAR+_1FRACTIONAL+_1/32DECIMALXX+_0.01XXX+_0.005HOLES+_0.007 | MATERIAL | TITLEThe COZYComponents for custom enclosures | |||||
| ANGULAR+_1FRACTIONAL+_1/32DECIMALXX+_0.01XXX+_0.005HOLES+_0.007 | MATERIAL | TITLEThe COZYComponents for custom enclosures | |||||
| ANGULAR+_1FRACTIONAL+_1/32DECIMALXX+_0.01XXX+_0.005HOLES+_0.007 | FINISH | TITLEThe COZYComponents for custom enclosures | |||||
| ANGULAR+_1FRACTIONAL+_1/32DECIMALXX+_0.01XXX+_0.005HOLES+_0.007 | MACHINEPROGRAM NO. | TITLEThe COZYComponents for custom enclosures | |||||
| THIS DRAWING IS PROPERTY OF KELVIN, AND IS TRANSMITTED IN CONFIDENCE.REPRODUCTION, USE OR DISCLOSURE, IN WHOLE OR IN PART, OF DESIGN AND DETAILS CONTAINED HEREIN IS PROHIBITED WITHOUT WRITTEN PERMISSION FROM KELVIN. | THIRD ANGLE PROJECTION | SIZE | REV | ||||
| THIS DRAWING IS PROPERTY OF KELVIN, AND IS TRANSMITTED IN CONFIDENCE.REPRODUCTION, USE OR DISCLOSURE, IN WHOLE OR IN PART, OF DESIGN AND DETAILS CONTAINED HEREIN IS PROHIBITED WITHOUT WRITTEN PERMISSION FROM KELVIN. | A | REV | |||||
| THIS DRAWING IS PROPERTY OF KELVIN, AND IS TRANSMITTED IN CONFIDENCE.REPRODUCTION, USE OR DISCLOSURE, IN WHOLE OR IN PART, OF DESIGN AND DETAILS CONTAINED HEREIN IS PROHIBITED WITHOUT WRITTEN PERMISSION FROM KELVIN. | SCALEAs Noted | DATE06/28/22 | SHEET1 | ||||
| THIS DRAWING IS PROPERTY OF KELVIN, AND IS TRANSMITTED IN CONFIDENCE.REPRODUCTION, USE OR DISCLOSURE, IN WHOLE OR IN PART, OF DESIGN AND DETAILS CONTAINED HEREIN IS PROHIBITED WITHOUT WRITTEN PERMISSION FROM KELVIN. | SCALEAs Noted | DATE06/28/22 | SHEET1 |
RADIATOR LABS
Custom Cover Components Clinton Hill Co-Ops
For Illustrative Purposes Only – Not Drawn to Scale
6.5 14” ”
2.75” 2.5” Figure 2: "Clamshell" Control Module
Figure 1: Crossflow Fan
4”
16.5” 19.5 ” 15” -- 12”
8.5” Figure 3: Duct – Isometric and Profile View Figure 4: Front Grille and Front Grille Housing.
The front grille is the air intake for the fan.
Figure 5: Generic Radiator Cover – Can be constructed out
of wood or metal but must have a front opening for the front grille. All interior surfaces must be insulated with thermoacoustic insulation (R Rating: 2.2)
RADIATOR LABS
RADIATOR LABS
Custom Cover Generic Installation Process Clinton Hill Co-Ops
Note: Not intended for installation instruction
1 2
Figure 5: Generic Radiator Cover Figure 6: Affix the Duct to the rear of the
Radiator Cover, and the front grille & front grille housing to the front.
4” Duct and Fan must sit between the Radiator and the front of the Enclosure, with a minimum distance of 4” between the two
4”
Figures 7 & 8: The Fan must be at the bottom of the duct, and there must be a minimum of 4” between the fan and the radiator fins. The Front Grille must be directly in front of the fan on the frontside of the enclosure.
RADIATOR LABS
Figure 9: The Clamshell Control Module must be secured to the outside of the Radiator Cover with a clear line-of-sight into the room
Figure 10: The enclosure must be insulated on all interior surfaces (top, front, sides) with no gaps. The insulation must have a R-rating of 2.2
Figure 10: A front view of the enclosure with the front grille for air intake and clamshell control module affixed. Note the clamshell control module does not need to be in the center. The front grille is required to be inserted into the cabinetry from the exterior.
Figure 11: Successful retrofit. Note the grill at the bottom for the fan and the Clamshell Control Module at the top, as well as the insulated riser.